  • Voltage compatibility: 100, 110, 120 or 127V AC
  • Frequency compatibility: 60 Hz
  • Output volt amp capacity (VA): 1050
  • Output watt capacity (watts): 670
  • Output nominal voltage: 100, 110, 120 or 127V AC nominal, user-selectable via back panel dip switches
  • Output voltage regulation: LINE MODE: Sine wave line voltage 120V (-12% / +5%), BATTERY MODE: Sine wave output 120V (+/-5%)
  • Output frequency regulation: LINE MODE: Passes line frequency of +/-10% BATTERY MODE: Inverter output regulated to 60Hz (+/- 1Hz)
  • Outlet quantity / type: 8 NEMA 5-15R
  • Customized load management receptacles: Output receptacles are arranged in a single load bank configuration that can be remotely controlled via software interface for scheduled or immediate reboot of connected equipment
  • Overload protection: Via 15A input breaker
  • Maximum input amps: 9.2 amps
  • Input connection type: NEMA 5-15P
  • Input cord length: 6 ft.
  • Recommended electrical service: 15A 120V
  • Full load runtime: 6 minutes (1050VA)
  • Half load runtime: 18 minutes (525VA)
  • DC system voltage: 36V DC
  • Typical battery lifespan: 3-6 years, depending on usage
  • Battery recharge rate: 4-8 hours to 90%
  • Voltage regulation description: Automatic Voltage Regulation (AVR) circuits maintain clean, regulated computer-grade 100, 110, 120, 127V nominal output, without using battery power, during brownouts to 91V and overvoltages to 145V
  • Overvoltage correction: Input voltages between 132 and 145V AC are reduced by 13%
  • Direct pass through: Input voltages between 106 and 131V AC are passed on to connected equipment unchanged
  • Brownout correction: Input voltages between 91 and 105 V AC are boosted by 17%
  • Front panel LEDs: Includes 14 front panel LEDs to indicate line / battery power status, over / under voltage correction, battery charge level (4 LEDs), load percentage (4 LEDs), overload and replace battery. Also includes 1 rear panel site wiring fault indicator.
  • Alarms: Audible alarms indicate BATTERY MODE (.4 sec. On / 4.6 sec. Off) and OVERLOAD (.4 sec. On / .6 sec. Off), UPS POWERED ON (single .4 sec. On)
  • AC surge suppression: 1800 joules
  • AC suppression response time: Instantaneous
  • EMI / RFI AC noise suppression: Yes
  • Unit weight (lbs): 43
  • Unit weight (kg): 19.5
  • Unit Dimensions (HWD/in): 8.75 x 6.75 x 16.75
  • Unit Dimensions (HWD/cm): 22.2 x 17.1 x 42.5
  • Material of construction: Steel
  • Form factors supported: Tower
  • Cooling method: Rear panel fan
  • Battery Access: Supports battery access and hot-swap replacement without powering connected equipment off
  • Operating Temperature: +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
  • Storage Temperature: +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
  • Relative Humidity: 0 to 95%, non-condensing
  • Line mode BTU/hr. (Max.): 58.4
  • Battery mode BTU/hr. (Max.): 370.8
  • Network monitoring port: Includes 2 built-in monitoring ports, 1-USB & 1-DB9
  • SNMP compatibility: Yes via external SNMP adapter accessory #SNMPWEBCARD
  • WatchDog compatibility: Yes, compatible with Tripp Lite's WatchDog Software
  • Transfer time from line power to battery mode: 4-8 milliseconds
  • Low voltage transfer to battery power: Switches to battery power as line voltage decreases to 90 volts or less. Resets back to line power mode as line voltage increases to 96 volts or higher.
  • High voltage transfer to battery power: Switches to battery power as line voltage increases to 145 volts or higher. Resets back to line power mode as line voltage decreases to 140V or less.
  • Certifications: UL1778 (USA), cUL (Canada), FCC Class B (emissions), IEC 1000-4-2 Level 3 (Electrostatic Discharge), IEC 1000-4-4 Level 2 (Fast Transient / Burst), IEC 1000-4-5 Level 3 (Lightning Surge)
  • Cold Start: Yes, inverter can be "cold started" to enable temporary AC output during a power failure by pressing and holding the POWER ON button for longer than 1 second.
  • Appearance: Attractive all-black tower UPS